Beskrivelse
CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber – Explosion-Proof
Control: 32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input for setpoints
Bwodsihb Amjpfx Ah Ssw
Error messages in plain text
RS 232 interface
Free switching channels for external test object control
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Heat radiation: approx. 1000 W at +20°C, approx. 200 W at -25°C
Nitrogen inertization with residual oxygen monitoring
With nitrogen inertization, the test chamber is initially purged with a large volume of N2 until the oxygen content is less than 3%. Afterwards, it switches to a base flow (approx. 10% of the large volume).
The nitrogen flow at the base quantity is measured by a flow meter, displayed, and monitored by a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it through an O2 sensor that monitors the residual oxygen content. The gas is then returned to the test chamber via a second flame arrestor. The extraction pump is monitored by a flow meter. For further details, refer to the Dräger operating manual attached.
The gas installation is currently out of service!
Technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test item, without heat radiation, and without additional equipment.
Dimensions:
Test volume: 950 liters
Test chamber internal dimensions: height approx. 700 mm / width approx. 900 mm / depth approx. 1500 mm
External dimensions: height approx. 2400 mm / width approx. 1270 mm / depth approx. 3125 mm
Operating Data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Nominal power: 21.6 kW
Nominal current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" female thread
Sound pressure level: < 62 dB(A)
(measured according to DIN EN ISO 3744, at a distance of 1m from the front)
Weight: approx. 1500 kg, control cabinet approx. 300 kg
External refrigeration unit
Refrigerant: R404A / R23
For your safety as a buyer, please note the following information!
The following items are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak check with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
We are happy to answer further questions by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Type: T-30/950 Ex/I
CTS Temperature Test Chamber – Explosion-Proof
Control: 32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input for setpoints
Bwodsihb Amjpfx Ah Ssw
Error messages in plain text
RS 232 interface
Free switching channels for external test object control
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Heat radiation: approx. 1000 W at +20°C, approx. 200 W at -25°C
Nitrogen inertization with residual oxygen monitoring
With nitrogen inertization, the test chamber is initially purged with a large volume of N2 until the oxygen content is less than 3%. Afterwards, it switches to a base flow (approx. 10% of the large volume).
The nitrogen flow at the base quantity is measured by a flow meter, displayed, and monitored by a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it through an O2 sensor that monitors the residual oxygen content. The gas is then returned to the test chamber via a second flame arrestor. The extraction pump is monitored by a flow meter. For further details, refer to the Dräger operating manual attached.
The gas installation is currently out of service!
Technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test item, without heat radiation, and without additional equipment.
Dimensions:
Test volume: 950 liters
Test chamber internal dimensions: height approx. 700 mm / width approx. 900 mm / depth approx. 1500 mm
External dimensions: height approx. 2400 mm / width approx. 1270 mm / depth approx. 3125 mm
Operating Data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Nominal power: 21.6 kW
Nominal current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" female thread
Sound pressure level: < 62 dB(A)
(measured according to DIN EN ISO 3744, at a distance of 1m from the front)
Weight: approx. 1500 kg, control cabinet approx. 300 kg
External refrigeration unit
Refrigerant: R404A / R23
For your safety as a buyer, please note the following information!
The following items are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak check with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
We are happy to answer further questions by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Din annonce er blevet slettet
Der opstod en fejl