Weiss
Model: WKL 100/40
Climate Test Chamber, Air-Cooled
with Humidity Control: -40 to +180°C
Specifications for Temperature Testing:
Temperature Range: -40 to +180°C
Temperature Deviations (stabilized conditions):
- Temporal fluctuation at chamber center: ±0.3 to ±1 K
- Spatial deviation: ±0.5 to ±2 K
Temperature Change Rate:
- Heating: 3.5 K/min
- Cooling: 5 K/min
Heat Compensation: max. 1100 W
Specifications for Climatic Testing:
Humidification System Data:
- Reservoir capacity: approx. 13 l
- Water quality: demineralized
- pH value: 6–7
- Conductivity: max. 20 μS/cm
- Water consumption at +40°C, 92% RH: 2 l / 24 h
- Temperature range: +10 to +95°C
- Humidity range: 10 to 98% RH
Temperature and Humidity Deviations (stabilized conditions):
- Temporal temperature fluctuation at chamber center: ±0.3 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temporal humidity fluctuation at chamber center: ±1 to ±3% RH
Mechanical Load Data:
- Maximum floor load in test chamber: 25 kg
- Per insert shelf: 10 kg
- Total loading of shelf supports: 50 kg
- Cable/pipe port right: 50 mm Ø
- Cable/pipe port left: 50 mm Ø
Interfaces:
- Ethernet (RJ45), USB interface
Operational Data:
- Test chamber lighting: halogen bulb 24V, 50W
- Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
- Rated power: 3.0 kW
- Rated current: 13.0 A
- Site fuse: 16A slow-blow (provided by customer)
Protection class:
- Control cabinet IP 22 and control panel IP 54
Heat emission, air-cooled test chambers:
- Max. heat emission to surroundings: 2000 W
Noise Measurement:
Ijdsxxtuispfx Agbstp
- Sound pressure level (free-field) measured at 1 m distance from front, 1.6 m height: approx. 56 dB(A)
Test chamber volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R-452a
For your safety as a buyer, please note the following information!
The following procedures are performed in advance on the chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to call us.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Model: WKL 100/40
Climate Test Chamber, Air-Cooled
with Humidity Control: -40 to +180°C
Specifications for Temperature Testing:
Temperature Range: -40 to +180°C
Temperature Deviations (stabilized conditions):
- Temporal fluctuation at chamber center: ±0.3 to ±1 K
- Spatial deviation: ±0.5 to ±2 K
Temperature Change Rate:
- Heating: 3.5 K/min
- Cooling: 5 K/min
Heat Compensation: max. 1100 W
Specifications for Climatic Testing:
Humidification System Data:
- Reservoir capacity: approx. 13 l
- Water quality: demineralized
- pH value: 6–7
- Conductivity: max. 20 μS/cm
- Water consumption at +40°C, 92% RH: 2 l / 24 h
- Temperature range: +10 to +95°C
- Humidity range: 10 to 98% RH
Temperature and Humidity Deviations (stabilized conditions):
- Temporal temperature fluctuation at chamber center: ±0.3 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temporal humidity fluctuation at chamber center: ±1 to ±3% RH
Mechanical Load Data:
- Maximum floor load in test chamber: 25 kg
- Per insert shelf: 10 kg
- Total loading of shelf supports: 50 kg
- Cable/pipe port right: 50 mm Ø
- Cable/pipe port left: 50 mm Ø
Interfaces:
- Ethernet (RJ45), USB interface
Operational Data:
- Test chamber lighting: halogen bulb 24V, 50W
- Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
- Rated power: 3.0 kW
- Rated current: 13.0 A
- Site fuse: 16A slow-blow (provided by customer)
Protection class:
- Control cabinet IP 22 and control panel IP 54
Heat emission, air-cooled test chambers:
- Max. heat emission to surroundings: 2000 W
Noise Measurement:
Ijdsxxtuispfx Agbstp
- Sound pressure level (free-field) measured at 1 m distance from front, 1.6 m height: approx. 56 dB(A)
Test chamber volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R-452a
For your safety as a buyer, please note the following information!
The following procedures are performed in advance on the chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to call us.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Registreret siden: 2012
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Din annonce er blevet slettet
Der opstod en fejl