Klimakammer med luftfugtighed 34 literWeiss
WKL 34/60 -60°C bis 150°C
Klimakammer med luftfugtighed 34 liter
Weiss
WKL 34/60 -60°C bis 150°C
Stand
Brugt
Beliggenhed
Borken 

Oplysninger om maskinen
Pris og placering
- Beliggenhed:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring op
Detaljer om tilbuddet
- Annonce-ID:
- A162-11179
- Referencenummer:
- 24134
- Opdatering:
- sidst den 15.11.2024
Beskrivelse
Weiss
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
Temperature range: -60°C to +150°C
Chamber volume: 34 liters
Standard pass-throughs included:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature testing:
Temperature range: -60°C to +150°C
Gbsdpfx Ajtr Dinepzjl
Temperature deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature variation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Specifications for climate testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature and humidity deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K (temperature gradient): 1 to 3
Temporal humidity fluctuation at working space center: ±3 to ±5% RH
Operating data:
Chamber lighting: Halogen bulb 12V, 20W
Nominal voltage: 1/N / PE AC 230 V ±10% 50 Hz
Nominal power: 2.5 kW
Nominal current: 11 A
On-site fuse: 16A slow-blow
Heat emission (air-cooled chambers):
Max. heat emission to environment: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally approved refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Amendments and errors in the technical data and specifications reserved!)
For further questions, please contact us by phone.
Annoncen er blevet oversat automatisk. Oversættelsesfejl kan forekomme.
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
Temperature range: -60°C to +150°C
Chamber volume: 34 liters
Standard pass-throughs included:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature testing:
Temperature range: -60°C to +150°C
Gbsdpfx Ajtr Dinepzjl
Temperature deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature variation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Specifications for climate testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature and humidity deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K (temperature gradient): 1 to 3
Temporal humidity fluctuation at working space center: ±3 to ±5% RH
Operating data:
Chamber lighting: Halogen bulb 12V, 20W
Nominal voltage: 1/N / PE AC 230 V ±10% 50 Hz
Nominal power: 2.5 kW
Nominal current: 11 A
On-site fuse: 16A slow-blow
Heat emission (air-cooled chambers):
Max. heat emission to environment: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally approved refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Amendments and errors in the technical data and specifications reserved!)
For further questions, please contact us by phone.
Annoncen er blevet oversat automatisk. Oversættelsesfejl kan forekomme.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Du kan også være interesseret i disse annoncer.
Lille annonce
Borken
520 km
Lille klimakammer 60 liter med luftfugtighed
CTSC-40/60 -40 bis +180°C
CTSC-40/60 -40 bis +180°C
Lille annonce
Borken
520 km
Walk-in klimakammer
WeissWK 27'/50-150 -50°C bis 150°C
WeissWK 27'/50-150 -50°C bis 150°C
Lille annonce
Borken
520 km
Shaker-system med forstærker
LDSV895-440 HBT900C + SPA50K
LDSV895-440 HBT900C + SPA50K
Lille annonce
Borken
520 km
Saltsprøjtekammer
KöhlerHK500
KöhlerHK500
Lille annonce
Borken
520 km
Shaker-system
LDSV875-440 LPT600C
LDSV875-440 LPT600C
Lille annonce
Borken
520 km
Klimakammer
DycometalCCK -40/1500 T 1500 Liter
DycometalCCK -40/1500 T 1500 Liter
Lille annonce
Borken
520 km
Gennemgangsklimakammer med fugt
RS-SimulatorenKKM 110/45 -40°C bis +120°C
RS-SimulatorenKKM 110/45 -40°C bis +120°C
Lille annonce
Borken
520 km
Prøvekammer til temperaturchok
Weiss130 Liter TS 130 *
Weiss130 Liter TS 130 *
Lille annonce
Borken
520 km
Stødprøvekammer
HeraeusHT 7012 S2
HeraeusHT 7012 S2
Lille annonce
Borken
520 km
Temperaturkammer 2000 liter
CTST-40/2000 -40°C bis +180°C
CTST-40/2000 -40°C bis +180°C
Din annonce er blevet slettet
Der opstod en fejl