Beskrivelse
CTS
Type: TSR-30/1000
Water-cooled
The type designation of the CTS cabinet series is structured as follows:
Example: Type TSR-30/1000
1) T stands for: Temperature
2) S stands for: Stress Screening
3) R stands for: External Conditioning
4) -30 indicates: lower temperature limit -30 °C
5) 1000 indicates: 1000 liters test chamber volume
Technical Performance Data:
A) TSR-30/1000 base unit without hose connections,
i.e., when used as a standalone temperature test chamber
Temperature testing:
Temperature range: -40°C to +180°C
Final temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Gsderivfcjpfx Af Iobu
Temperature change rate according to IEC 60068-3-5
Heating: 6.0 K/min
Cooling: 5.0 K/min
Heat radiation:
Approx. 5000 W at +20°C
Approx. 4200 W at ±0°C
Approx. 3000 W at -20°C
Technical data are based on ambient temperature of +25°C,
Nominal voltage 400V, without test specimen, without heat input and without additional equipment.
Air volume flow
Approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to a customer-provided external test chamber
Temperature testing:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate,
measured with a closed-loop circuit
Heating: 4.0 K/min
Cooling: 4.0 K/min
within the range +150°C to -10°C
Technical data are based on ambient temperature of +25°C,
Nominal voltage 400V, without test specimen, without heat input and without additional equipment,
measured in a closed-loop circuit
Note: The customer-provided external test chamber must be completely sealed and properly insulated;
any penetrations must be optimally sealed by the customer.
Dimensions:
Test volume: 1000 liters
Recirculating air connection: Ø 200 mm
Test space dimensions: Height 900 mm, Width 1000 mm, Depth 1100 mm
External dimensions: Height 1950 mm, Width 1270 mm, Depth 2245 mm
Technical Design:
Refrigeration unit:
water-cooled, low-noise full hermetic design
stepless performance adjustment via
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully openable, left-hinged door,
one-hand operation, lockable.
Shelf grate:
stainless steel, support area 970 x 980 mm
Load capacity per shelf max. 35 kg
Total load with max. shelves: 100 kg
Test chamber lighting: halogen lamp 20 W, 12 V
Control system:
- 32-bit controller
- LCD control panel
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 13.3 kW
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, please note the following information!
The following points are checked or serviced in advance on our offered chambers:
1. Function check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Alterations and errors in the technical data and information reserved!)
For further questions, we are happy to assist you by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Type: TSR-30/1000
Water-cooled
The type designation of the CTS cabinet series is structured as follows:
Example: Type TSR-30/1000
1) T stands for: Temperature
2) S stands for: Stress Screening
3) R stands for: External Conditioning
4) -30 indicates: lower temperature limit -30 °C
5) 1000 indicates: 1000 liters test chamber volume
Technical Performance Data:
A) TSR-30/1000 base unit without hose connections,
i.e., when used as a standalone temperature test chamber
Temperature testing:
Temperature range: -40°C to +180°C
Final temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Gsderivfcjpfx Af Iobu
Temperature change rate according to IEC 60068-3-5
Heating: 6.0 K/min
Cooling: 5.0 K/min
Heat radiation:
Approx. 5000 W at +20°C
Approx. 4200 W at ±0°C
Approx. 3000 W at -20°C
Technical data are based on ambient temperature of +25°C,
Nominal voltage 400V, without test specimen, without heat input and without additional equipment.
Air volume flow
Approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to a customer-provided external test chamber
Temperature testing:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate,
measured with a closed-loop circuit
Heating: 4.0 K/min
Cooling: 4.0 K/min
within the range +150°C to -10°C
Technical data are based on ambient temperature of +25°C,
Nominal voltage 400V, without test specimen, without heat input and without additional equipment,
measured in a closed-loop circuit
Note: The customer-provided external test chamber must be completely sealed and properly insulated;
any penetrations must be optimally sealed by the customer.
Dimensions:
Test volume: 1000 liters
Recirculating air connection: Ø 200 mm
Test space dimensions: Height 900 mm, Width 1000 mm, Depth 1100 mm
External dimensions: Height 1950 mm, Width 1270 mm, Depth 2245 mm
Technical Design:
Refrigeration unit:
water-cooled, low-noise full hermetic design
stepless performance adjustment via
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully openable, left-hinged door,
one-hand operation, lockable.
Shelf grate:
stainless steel, support area 970 x 980 mm
Load capacity per shelf max. 35 kg
Total load with max. shelves: 100 kg
Test chamber lighting: halogen lamp 20 W, 12 V
Control system:
- 32-bit controller
- LCD control panel
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 13.3 kW
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, please note the following information!
The following points are checked or serviced in advance on our offered chambers:
1. Function check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Alterations and errors in the technical data and information reserved!)
For further questions, we are happy to assist you by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Din annonce er blevet slettet
Der opstod en fejl